Serum Amyloid A Protein/C Reactive Protein (hs-CRP+CRP) Rapid Test
REF:PMDGC
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:assists in identifying bacterial/viral infections;auxiliary assessment of the course of infectious disease;guidance on the rational use of antibiotics
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:Serum or plasma: 5μL
Whole blood: 10μL
Linear range:SAA:5-150 mg/L
CRP:0.5-200 mg/L
LOD:CRP:<10.00 mg/L
hs-CRP:<3.00 mg/L
SAA:<10.00 mg/L
Detection time( min):5min
Applicable Department:ICU, transplant surgery, neonatology, pediatrics, surgery, internal medicine, etc
Supporting Instruments:PMDT9000;PMDT9100
-
C Reactive Protein (hs-CRP+CRP) Rapid Test
REF:PMDGA
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:assists in the diagnosis of sepsis and severe bacterial infections;guidance on the rational use of antibiotics;assists in the differential diagnosis of local and sustemic bacterial infections
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:Serum or plasma: 5μL
Whole blood: 10μL
Linear range:0.50μg/mL200.00μg/mL
LOD:CRP:<10.00 μg/mL
hs-CRP:<3.00 μg/mL
Detection time( min):5min
Applicable Department:ICU, transplant surgery, neonatology, pediatrics, surgery, internal medicine, etc
Supporting Instruments:PMDT9000;PMDT9100
-
Procalcitonin Rapid Test
REF:PMDFL
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:systemic bacterial infections;sepsis recognition
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:70 μl
Linear range:0.10ng/mL-40.00ng/mL
LOD:<0.50 ng/mL
Detection time( min):15min
Applicable Department:ICU, transplant surgery, neonatology, pediatrics, surgery, internal medicine, etc
Supporting Instruments:PMDT9000;PMDT9100
-
CK-MB Rapid Test
REF:PMDFL
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:diagnosis of myocardial injury;evaluation of myocardial infarction
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:100 ul
Linear range:3-80ng/mL
LOD:<5.0 ng/ mL
Detection time( min):10min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
MYO Rapid Test
REF:PMDFK
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:diagnosis of myocardial injury;evaluation of myocardial infarction
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:70 μl
Linear range:50-400ng/mL
LOD:<70.00ng/ mL
Detection time( min):10min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
cTnI/Myo/CK-MB Rapid Test
REF:PMDFI
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:diagnosis of myocardial ingury;ecaluation of myocardial infarction
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:100 μl
Linear range:cTnI: [0.3,25] ng/ml;
Myo: [25,500] ng/ml;
CK-MB:[2.5,300] ng/ml
LOD:cTnI:<1.00ng/ mL;
Myo:<70.00ng/ mL;
CK-MB:<5.00ng/ mL.
Detection time( min):15min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
ST2 Rapid Test
REF:PMDFD
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:early recognition;risk evaluation;prognostic assessment of heart failure
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:70 μl
Linear range:5.00-200.00ng/mL
LOD:<35.00ng/ mL
Detection time( min):15min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
ST2/NT-proBNP Rapid Test
REF:PMDFE
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:comprehensive management of heart failure
Performance Parameter:Sample:serum/plasma
Sample dosage:100 μl
Linear range:sST2: 5.00-200.00ng/mL
NT-proBNP: 100.00-20000.00pg/mL
LOD:sST2:<35.00ng/ mL
NT-proBNP:<300.00 pg/mL
Detection time( min):15min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
cTnI Rapid Test
REF:PMDFJ
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:makers of myocardial injury
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:70 μl
Linear range:0.2ng/mL-40.00ng/mL
LOD:<1ng/ mL
Detection time( min):10min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
NT-proBNP Rapid Test
REF:PMDFB
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:diagnosis of heart failure; identification of dyspnea
Performance Parameter:Sample:serum/plasma/whole blood
Sample dosage:100 μl
Linear range:30.00pg/mL-30000.00pg/mL
LOD:<300.00 pg/mL
Detection time( min):15min
Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
D-Dimer Rapid Test
REF:PMDFA
Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;
30 tests/kit; 40 tests/kit; 50 tests/kit
Clinical Significance:activation evaluation of coagulation and fibrinolysis
Performance Parameter:Sample:plasma/whole blood
Sample dosage:70 μl
Linear range:200.00ng/mL-5000.00ng/mL
LOD:<500ng/mL
Detection time( min):10min
Applicable Department:Chest pain center, emergency department, cardiology department, ICU/CCU, etc
Supporting Instruments:PMDT9000;PMDT9100
-
Fluorescence immunochromatography analyzer
REF:PMDNC-01
Performance Parameter:Power requirements:AC220, 50Hz
Sample dosage:Whole blood/serum/plasma/peripheral blood/urine
Channels number:1
Printing mode: including thermal printer, Applies to external printer
Detection time( min):5-15min
Size:267*220*140mm
Applicable Department:laboratory, point-of-care, ICU/CCU